TM-5-3895-372-20

CONCRETE-MOBILE MIXER BODY M919, MODEL 8CM-24/F

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL

AUGUST 1980

  TM-5-3895-372-20 - Page 140 of 694

TM 5-3895-372-20
WATER SYSTEM.
5-8. STRAINER MAINTENANCE (Continued).
LOCATION/ITEM
ACTION
REMARKS
B. CLEANING AND INSPECTION.
7.
Strainer (3).
a. Shake off large pieces of
dirt.
b. Clean with soap and water
If it can’t be cleaned, replace.
and brush.
c. Allow to dry.
d. Inspect for holes.
8.
Water shutoff valve (1).
Open slightly. When all dirt is
rinsed out of strainer housing,
close.
C. INSTALLATION.
9.
Strainer (3).
Place in position.
10.
Cap (2).
Put on.
11.
Bracket (5).
Swing into place.
12.
T-handle (4).
Turn clockwise to tighten.
13.
Draincock (6).
Close.
14.
Water shutoff valve (1).
Open. Check for leaks.
5-12


Back to Top