WATER SYSTEM.
5-9. WATER PUMP MAINTENANCE (Continued).
LOCATION/ITEM
ACTION
REMARKS
B. INSTALLATION (Continued).
25.
Hose (19).
Install.
26.
Hose clamps (20).
Slide into position and tighten.
27.
V-belts (18).
Install.
C. ADJUSTMENT
28.
Refer to para 4-11.
NOTE
Follow-on maintenance action required:
a.
Close water pump draincock. Refer to TM 5-3895-372-10.
b.
Open shut-off valve. Refer to para 5-12.
5-18