TM 5-3896372-20
WATER SYSTEM.
5-13. FLOW CONTROL VALVE MAINTENANCE.
THIS TASK COVERS: (APPROXIMATE TIME REQUIRED FOLLOWS TASK DESCRIPTION.)
a. Removal.
(20)
b. Installation.
(20)
c. Operational Check.
( 5)
45 Minutes Total.
INITIAL SETUP
EQUIPMENT
CONDITION
PARAGRAPH
CONDITION DESCRIPTION
5-12A.
Shut Off Valve Closed.
APPLICABLE CONFIGURATIONS
M919.
TEST EQUIPMENT
None.
SPECIAL TOOLS
None.
MATERIALS/PARTS (P/N)
Liquid Teflon (Refer to Appendix C).
PERSONNEL REQUIRED
SPECIAL ENVIRONMENTAL CONDITIONS
One (MOS-62B20).
Vehicle Parked on Level Ground.
REFERENCES (TM)
GENERAL SAFETY INSTRUCTIONS
TM 9-2320-273-10.
Engine Off.
TM 5-3895-372-10.
Transmission in Neutral.
TM 5-3895372-20P.
Parking Brake Set.
TROUBLESHOOTING REFERENCES
Table 5-1.
5-34