TM-5-3895-372-20

CONCRETE-MOBILE MIXER BODY M919, MODEL 8CM-24/F

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL

AUGUST 1980

  TM-5-3895-372-20 - Page 156 of 694

TM 5-3895-372-20
WATER SYSTEM.
5-11.
SIGHT GAGE MAINTENANCE (Continued)
LOCATION/ITEM
ACTION
REMARKS
B.
CLEANING.
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi.
Use only with effective chip guarding
and personal protective equipment (goggles/shield,
gloves,
etc.).
Do not allow dry cleaning solvents,
such as SD-2,
to come in contact with seals or flexible hoses.
These
cleaners may damage leather,
rubber,
and synthetic materials.
6.
Gage-tube (1).
a.
Clean with soap and water.
b.
If dirt or scum remains,
use
dry cleaning solvent SD-2.
Dry with compressed air.
7.
Air vent (7).
Pull from gage tube (1) and
Replace as necessary.
inspect for blockage and
deterioration.
C.
INSTALLATION.
8.
Air vent (7).
Install onto top of gage tube (1).
9.
Three grommets (2).
Install into three gage tube
brackets (6).
10. Gage collar nut (3)
a.
Slide gage tube (1) down
and gage tube (1).
thru the gage tube brackets
(6)and grommets (2).
b.
Slide gage collar nut (3) over
bottom end of gage tube (1).
c.
Insert gage tube (1) into top
Install with red line in gage tube
of gage valve (4) and secure
toward center of vehicle.
with gage collar nut (3).
11. Draincock (5) and
Close draincock (5) and open
Check for leaks and retighten
gage valve (4).
gage valve (4).
Gage tube (1)
gage collar nut (3) as necessary.
should fill to level of water
in tank.
5-28