TM 5-3895-372-20
ADMIX SYSTEMS.
6-10.
FLOWMETERS MAINTENANCE (Continued).
LOCATION/ITEM
ACTION
REMARKS
C .
OPERATIONAL CHECK (Continued).
NOTE
Repeat steps 28 thru 30 four more times.
31. Worksheet.
a.
Add the five amounts you
wrote down.
b.
Divide by five.
Your
answer should be 6 qts,
+ 1/8 qt, (or 4 oz), (5.68
liters i 0.12 liters).
NOTE
If your answer is not within acceptable limits perform steps 32 thru 36.
32. Air pressure gage.
Check pressure.
Must be 14’ -
Adjust pressure.
15X psi (100-107 kPa).
33. Solution tank.
Check for air or liquid
Replace, if necessary.
leaks.
34. Pipes, flexible hoses,
Check for leaks or blockage.
Remove blockage or
and connections.
replace part.
35. Valves and tank
Check for leaks or blockage
Remove blockage or
down pipe.
and functioning. replace part.
36. Pressure gage.
Insert test gage between
If admix air pressure
admix air pressure gage
gage is faulty, replace it.
and gate valves.
Compare
readings.
NOTE
Recheck operation check after performing steps 32 thru 36.
6-28


Back to Top