TM-5-3895-372-20

CONCRETE-MOBILE MIXER BODY M919, MODEL 8CM-24/F

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL

AUGUST 1980

  TM-5-3895-372-20 - Page 226 of 694

TM 5-3895-372-20
ADMIX SYSTEMS.
6-11.
FLOWMETERS REPAIR (Continued).
LOCATION/ITEM
ACTION
REMARKS
B.
CLEANING AND INSPECTION.
11. Flowmeter.
a.
Clean all parts of sediment
Clean in solvent.
Do not
and admix build-up.
allow rubber components
to come in contact with
solvent.
b.
Replace any parts that
are damaged and/or are
not able to be cleaned
sufficiently.
C.
ASSEMBLY.
12. Retainer stem (2).
Install.
Through inside of
and retainer (3).
housing.
13. Jam nut (1).
Install.
Hold setscrew (11) with
hex key wrench while
turning nut.
Do not
tighten.
14. Retainer stem (2)
Retract into end fitting until
and retainer (3).
retainer is flush with bottom
of end fitting.
15. Lower spring (8).
Install in meter tube.
16. Float (6).
Install in meter tube.
Pin wheel towards
spring.
17. Upper spring (5).
Install in meter tube.
18. Meter tube (7).
Install in housing and center
Calibration numbers
in 0-rings (4).
toward the front.
CAUTION
If tube is not centered in O-rings when tightening, damage to the meter tube will occur.
19. Retainer stem (2).
Tighten carefully until meter
Use hex key wrench.
cannot be rotated with fingers.
6-32


Back to Top