TM 5-3895-372-20
ADMIX SYSTEMS
6-18. ADMIX INJECTOR MAINTENANCE (Continued).
LOCATION/ITEM
ACTION
REMARKS
A. REMOVAL.
1.
Swivel nut (1).
Remove.
2.
Swivel nut (5).
Remove.
3.
Injector assembly (3).
Remove.
4.
Adapter (4).
Remove.
5.
450 elbow (2).
Remove.
B. INSTALLATION.
6.
450° elbow (2).
Install.
Coat threads with liquid teflon.
7.
Adapter (4).
Install.
Coat threads with liquid teflon.
8.
Injector assembly (3).
Install.
Coat with liquid teflon.
9.
Swivel nut (5).
Install.
10.
Swivel nut (1).
Install.
C. OPERATIONAL CHECK.
11.
Air and solution gate valves.
Open.
12.
Flowmeters.
Set to 5.8 gallons per
minute approximately.
13.
Quick opening valve.
Open.
a.
Check for leaks at hose
joints.
b.
Check that admix solution
flows freely.
6-60