TM-5-3895-372-20

CONCRETE-MOBILE MIXER BODY M919, MODEL 8CM-24/F

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL

AUGUST 1980

  TM-5-3895-372-20 - Page 247 of 694

TM 5-3895-372-20
ADMIX SYSTEMS
6-17. AIR RELIEF VALVE MAINTENANCE AND ADJUSTMENT (Continued).
LOCATION/ITEM
ACTION
REMARKS
A. REMOVAL.
NOTE
The following procedure may be used for both liquid admix tank air relief valves. Make
certain that the air shutoff valve is closed and pressure is drained from liquid admix tanks
before proceeding.
1.
Air relief valve (2).
Remove from nipple (1).
Place in vise.
6-53


Back to Top