TM 5-3895-372-20
ADMIX SYSTEMS
6-16. LIQUID ADMIX TANKS MAINTENANCE (LOW-FLOW) (Continued).
LOCATION/ITEM
ACTION
REMARKS
A. REMOVAL (Continued).
1.
Swivel nut (2).
Disconnect.
2.
Hose fitting (9).
Remove. Remove hose (1)
from vehicle.
3.
Swivel nut (7).
Disconnect.
4.
Swivel nut (15).
Disconnect.
5.
Strainer (10).
Remove.
6.
Lower plumbing (14).
Revolve counterclockwise
until parallel with tank.
7.
Four bolts (13) and
Remove two straps (6) and
locknuts (12).
mounting pads (17).
8.
Tank (16).
Remove.
9.
Air gage and regulator
Remove at nipple (5).
(8).
10.
Filler cap (4).
Remove.
11.
Air valve and plumb-
Remove at nipple (3).
ing components.
12.
Lower plumbing (14).
Remove at nipple (11).
B. INSTALLATION.
NOTE
Use liquid teflon on all threaded joints at assembly.
13.
Valve and lower
Install at nipple (11).
Plumbing should face the rear
plumbing (14).
and parallel with tank.
Change 1
6-48