TM 5-3895-372-20
CEMENT SYSTEM.
8-13.
METER REGISTER CABLE MAINTENANCE (Continued).
LOCATION/ITEM
ACTION
REMARKS
A.
REMOVAL (Continued).|
4. Setscrew (1).
5. Clamp (9), bolt (8),
washer (10), and nut (11).
6. Two adapters (4).
7. Two spring pins (6).
B.
LUBRICATION.I
8. Core (7).
C.
INSTALLATION.
9. Core (7).
10. Cable assembly (12).
11. Two adapters (4).
12. Two drives (3) and (13).
13. Two bolts (8).
D.
OPERATIONAL CHECK.
14. Meter feeder (14).
Loosen.
a. Loosen and remove.
b. Pull
cable
assembly
(12)from
meter
feeder
(14).
Loosen two setscrews (5)
and remove two drives
(3) and (13).
Push from adapters (4) and
remove adapters from cable
assembly (12).
Remove from cable assembly
(12) and grease thoroughly
with GAA.
Reinstall.
a.
Position into two clamps (9).
b.
Install two bolts (8), washers
(10), and nuts (11).
Position on core (7) and install
two spring pins (6).
a.
Position into two adapters
(4) and lock with two set-
screws (5).
b.
Insert drive (13) into meter
feeder (14) and lock with set-
screw (1).
c.
Insert drive (3) into meter
register (2).
Tighten at clamps (9) to secure
cable assembly (12).
a.
Disengage cement bin clutch.
b.
Turn meter feeder manually.
c.
Check that meter register
count changes with each turn.
Turn meter feeder (14) until
setscrew (1) is accessible.
Do not tighten bolts (8) at
this time.
See TM 5-3895-372-10.
8-38


Back to Top