TM-5-3895-372-20

CONCRETE-MOBILE MIXER BODY M919, MODEL 8CM-24/F

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL

AUGUST 1980

  TM-5-3895-372-20 - Page 494 of 694

TM 5-3895-372-20
HYDRAULIC SYSTEM.
10-10.
RELIEF VALVE ADJUSTMENT (Continued).
LOCATION/ITEM
ACTION
REMARKS
A TEST PRESSURE (Continued).
3.
Mixer-auger.
Hold with auger stop tool,
turn
slowly until wrench lodges
against side of trough.
Do not
allow auger to turn while you
test hydraulic pressure.
4.
Mixer body.
Start up and engage PTO.
(Re-
fer to TM 9-2320-273-10.)
5.
Hand throttle,
tachometer.
Adjust throttle until tacho-
Maintain this pump speed
meter reads 1250.
throughout test.
WARNING
Do not open valve quickly or wrench will be thrown free.
Turn valve slowly until completely open.
6.
Hydraulic control valve.
Open as if starting hydraulic
motor.
7.
Bypass valve.
Close slowly.
Continue until valve is com-
pletely closed.
8.
Pressure gage.
Read.
Pressure should be
a.
If pressure is correct,
go to
1900C2000 psi (13,10
Part C.
13,800 kPa).
b.
If pressure needs adjust-
ment,
go to Part B.
Do not lose copper gasket.
B.
ADJUSTMENT.
9.
Acorn nut (1) and
Remove.
copper gasket (3).
10. Jam nut (4).
Loosen.
11. Adjusting screw (2).
Turn until pressure reaches
Turn clockwise to increase
1950 (13,450 kPa).
pressure.
10-24


Back to Top