TM-5-3895-372-20

CONCRETE-MOBILE MIXER BODY M919, MODEL 8CM-24/F

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL

AUGUST 1980

  TM-5-3895-372-20 - Page 496 of 694

TM 5-3895-372-20
HYDRAULIC SYSTEM.
10-10.
RELIEF VALVE ADJUSTMENT (Continued).
LOCATION/ITEM
ACTION
REMARKS
B.
ADJUSTMENT (Continued).
12.
Jam nut (4).
Tighten.
13.
Copper gasket (3) and
Screw on and tighten.
acorn nut (1).
14.
Pressure gage.
Read.
Pressure should be
1900-2000 psi (13,100-
13,800 kPa).
NOTE
If you are unable to obtain proper pressure,
refer problem to Direct Support Maintenance.
C.
GAGE REMOVAL.
15.
Control valve.
Close.
16.
Engine.
Shut down.
Refer to
Ta1
9-2320-
273-10.
17.
Auger stop-tool.
Remove from auger.
18.
Pressure gage.
Remove.
19.
Pipe plug (5).
Install.
10-26


Back to Top