TM 5-3895-372-20
ELECTRIC WINCH.
12-8.
HYDRAULIC MOTOR MAINTENANCE (Continued).
LOCATION/ITEM
ACTION
REMARKS
A. REMOVAL (Continued).
4.
Winch control box.
Press the LOWER button until
cable is completely paid out.
5.
Two nuts, lockwashers,
Remove.
and bolts (3).
6.
Clamp (4).
Remove.
7.
Setscrew (9).
Loosen.
8.
Cable (2).
Pull out of stop sleeve (8) and
reel (1).
Remove the cable.
B. CLEANING AND LUBRICATION.
9.
Cable (2).
a. Wipe with a damp rag.
b. Inspect for rust or fraying.
Replace if necessary.
c. Oil with CW.
d. Wipe off excess oil.
C. INSTALLATION.
10. Cable (2).
a. Thread through three
pulleys on trough
support frame.
b. Thread through hole in
reel (1) and through
stopsleeve (8).
11. Setscrew (9).
Tighten.
12. Clamp (4).
Slide spool toward motor and
gear box, and install clamp
around shaft.
13. Two nuts, lockwashers,
Install and tighten securely.
and bolts (3).
14. Cable end (7).
a. Thread through pulley on
trough.
b. Thread through anchor (6)
and back through two
clamps (5).
12-10