CORRECTIVE ACTION - Continued
2.
Disconnect and reconnect BAP air line quick-disconnect connector and ensure connector locks
(Figure 1).
a.
If locks do not work and/or an air leak is heard, notify Field maintenance.
b.
If front pin locks do not work during air-release procedure, manually release front locks to
deploy bridge bay. (WP
0008) Notify Field maintenance upon completion of mission.
END OF WORK PACKAGE