CORRECTIVE ACTION - Continued
HYDRAULIC CABINET COVER
FLATWASHER
SCREW
MAIN
JUNCTION
BOX
Figure 5.
Hydraulic Cabinet Cover.
2.
Disconnect right hand connector J3 (40 pin connector) from digital controller (Figure 6).
POSITION 1
WINCH OUT
SOLENOID
CONNECTOR
WINCH OUT
SOLENOID
AND VALVE
POSITION 2
POSITION
35
POSITION 35
J3
J4
POSITION
33
POSITION 5
POSITION 1
Figure 6.
Connector J3 and Connector J4.
3.
Disconnect left hand connector J4 (40 pin connector) from digital controller (Figure 6).
4.
Remove connector from WINCH OUT solenoid (Figure 6).
5.
Set multimeter to ohms position.
NOTE
A reading of infinity indicates an open circuit.
6.
Place negative (-) probe of multimeter on position 1 of digital controller wiring harness connector
J4 (Figure 6).
7.
Place positive (+) probe of multimeter on position 2 of digital controller wiring harness connector
P2 (Figure 7). Check multimeter for continuity.