TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 451 of 1188

TM 5-4210-249-13&P-1
0076-3
DRAFT
0076
TFFT03721
Step 3.
Turn battery disconnect switch to OFF position (WP 0007).
Open pump operator’s
panel (WP 0019).
While an assistant puts pump operator’s panel START PUMP
ENGINE STOP switch to START position (WP 0004), check for continuity across pump
operator’s panel START PUMP ENGINE STOP switch from terminal wire 4072 (green)
to terminal wire 4070 (white).
If there is no continuity, replace pump operator’s panel START PUMP
ENGINE STOP switch (WP 0330).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top