Step 6.
Operate personnel cab pressure governor in RPM mode (WP 0024).
Check if pump
operator’s panel pressure governor changes water pump engine speed when operated
(WP 0024).
If personnel cab pressure governor does not operate (WP 0024), go to
Step 9
TFFT04407
NOTE
The message center must display MODE on personnel cab governor control panel, before
entering the password.
Message center will display xxx3-5xx after entering self-test
password.
Step 7.
Perform pressure governor self-test on personnel cab pressure governor by entering
self-test password IDLE INC IDLE INC IDLE INC IDLE INC.
Press each key on
personnel cab pressure governor, watch message display for a letter indicating which
switch is being pressed.
Once all switches, on personnel cab pressure governor are
pressed, a “2” will be displayed in position 2.
If a letter is displayed constantly, letter is not displayed when pressed, or “2”
is not displayed in position 2, replace personnel cab governor control
panel (WP 0309).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION