NOTE
The message center must display MODE on pump operator’s panel governor control
panels, before entering the password.
Message center will display xxx3-5xx after
entering self-test password.
Step 7.
Reconnect pump operator’s panel wire harness pump operator’s panel pressure
governor 12-terminal wire harness connector.
Reconnect pump operator’s panel
pressure governor pressure transducer wire harness connector.
Turn battery
disconnect switch to ON position (WP 0007).
Start water pump engine (WP 0022).
Push MODE switch on pump operator’s panel pressure governor control panel.
Perform governor control panel self test on pump operator’s panel governor control by
entering self-test password IDLE INC IDLE INC IDLE INC IDLE INC.
Check for “5”, H
or F in position 5 when display enters self-test mode.
a.
If pump operator’s panel pressure governor displays “5” or H in
position 5, replace pump operator’s panel pressure governor
panel (WP 0332).
b.
If pump operator’s panel governor displays
F in position
5, replace
pump operator’s panel pressure governor pressure transducer
(WP 0411).