TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 471 of 1188

TM 5-4210-249-13&P-1
0078-9/(10 blank)
DRAFT
0078
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
TFFT04433
NOTE
The message center must display MODE on pump operator’s panel pressure governor
MESSAGE CENTER before entering the password.
Message center will display
xxx3-5xx after entering self-test password.
Step 14.
Connect main wire harness personnel cab pressure governor 12-terminal wire harness
connector.
Connect personnel cab pressure governor pressure transducer wire
harness connector.
Turn battery disconnect switch to ON position (WP 0007).
Start
water pump engine (WP 0022).
Push MODE switch on personnel cab pressure
governor (WP 0004).
Perform governor control panel self test on personnel cab
pressure governor control by entering self-test password IDLE INC IDLE INC IDLE INC
IDLE INC.
Check for “5”, H or F in position 5 when display enters self-test mode.
a.
If personnel cab pressure governor displays “5” or H in position 5,
replace personnel cab pressure governor control panel (WP 0309).
b.
If personnel cab pressure governor displays F in position 5, replace
personnel cab pressure governor pressure transducer (WP 0411).


Back to Top