TM 5-4210-249-13&P-1
0078-4
DRAFT
0078
TFFT04429A
Step 5.
With a test lead set, check for continuity across white wire from pressure transducer
connector, terminal 3 to pressure governor 12-terminal connector, terminal 7.
If continuity is not present, replace pressure transducer wire
harness (WP 0460).
Step 6.
With a test lead set, check for continuity across black wire from pressure transducer
connector, terminal 2 to pressure governor 12-terminal connector, terminal 5.
If continuity is not present, replace pressure transducer wire
harness (WP 0460).