TM-5-4210-249-13-P-1

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 1 OF 4

  TM-5-4210-249-13-P-1 - Page 654 of 1188

TM 5-4210-249-13&P-1
0099-8
DRAFT
0099
TFFT03394
Step 8.
Remove pump house panel S (WP 0540).
Put cab FOAM SYSTEM switch to off
position (WP 0004).
Put GROUND SWEEPS switch to off position (WP 0004).
Check
air lines from FOAM B shutoff valve control manifold to foam system flow control
manifold for leaks, kinks, or damage.
If air lines are not free from leaks, kinks, or damage, replace damaged air
lines (WP 0567).
Step 9.
Check lines from GROUND SWEEPS FOAM B foam system flow control manifold to
ground sweeps foam B multi-metering valve cylinder for leaks, kinks, or damage.
If air lines are not free from leaks, kinks, or damage, replace damaged air
lines (WP 0567).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top