TM 5-4210-249-13&P-1
0105-1
DRAFT
0105
FIELD LEVEL MAINTENANCE
DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE)
INITIAL SETUP:
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE)
NOTE
•
Ensure cap is installed tightly on DIRECT TANK FILL during this procedure, or connect
hose to DIRECT TANK FILL connector to drain water into appropriate container or to
ground.
If direct tank fill valve opens during this procedure, water will discharge from tank
uncontrolled.
•
Do not engage water pump engine during this procedure.
Valve operation can be checked
without pump operation.
•
Valve operations can be checked by observing valve shaft rotation.
•
If it is known that direct tank fill valve operates properly in manual mode, go to Step 2.
Tools and Special Tools
Lead Set, Test (WP 0622, Item 21)
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Personnel Required
MOS 63B Wheeled vehicle mechanic (2)
References
TM 9-2320-325-14&P
WP 0004
WP 0007
WP 0123
WP 0303
WP 0540
WP 0325
WP 0337
WP 0339
References (continued)
WP 0412
WP 0413
WP 0418
WP 0441
WP 0447
WP 0457
WP 0458
WP 0459
WP 0499
WP 0463
Equipment Conditions
Water pump engine OFF (WP 0022)
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)