TM 5-4210-249-13&P-2
0248-1
DRAFT
0248
FIELD LEVEL MAINTENANCE
WATER PUMP ENGINE STARTER MOTOR REPLACEMENT
INITIAL SETUP:
REMOVAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Tag and mark connectors prior to removal to ensure proper installation.
1.
Disconnect three connectors (1) from pump house heater assembly (2).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00340
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Tags, Identification (WP 0625, Item 51)
Sealant, RTV200 Electrical (WP 0625, Item 47)
Lockwasher (1)
References
WP 0615, Fig. 25
Equipment Conditions
Pump house panel G removed (WP 0540)