TM 5-4210-249-13&P-2
0286-2
DRAFT
0286
INSTALLATION
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
CAUTION
Use pipe thread sealing compound sparingly only on pipe threads.
Do not apply
compound to hose connections.
Damage to equipment may result.
1.
Install elbow (3) and nipple (6) on foam system eductor (4) (WP 0489).
2.
Install foam system eductor (4) on pipe (5) (WP 0489).
3.
Install hose (2) and coupling (1) on elbow (3) (WP 0483).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install foam system inlet check valve (WP 0290)
2.
Install primer valve (WP 0267)
END OF TASK
END OF WORK PACKAGE
TFFT0270
WARNING
ICON 30, 44, 27