TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 175 of 1452

TM 5-4210-249-13&P-2
0132-5/(6 blank)
DRAFT
0132
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
TFFT2601
Step 4.
Turn battery disconnect switch to ON position (WP 0007).
Turn FOAM FLUSH switch
on (WP 0004).
Check for 22 to 28 VDC between pump operator’s panel wire harness
wire 2849 (yellow) from pump operator’s panel FOAM FLUSH indicator to a known
good ground.
a.
If 22 to 28 VDC are present, replace pump operator’s panel FOAM
FLUSH indicator (WP 0326).
b.
If 22 to 28 VDC are not present, repair wire 2849 in pump operator’s
panel wire harness if repairable (TM 9-2320-325-14&P), or replace
pump operator’s panel wire harness (WP 0459).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top