TM 5-4210-249-13&P-2
0164-5
DRAFT
0164
TFFT03845
NOTE
Circuit breaker may be in ON position when tripped.
To make sure circuit breaker is not
tripped, reset circuit breaker by switching it to OFF position, then back to the ON position.
Step 6.
Reset circuit breaker (WP 0021).
Check for continuity across circuit breaker.
If there is no continuity, replace circuit breaker (WP 0362).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top