TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 531 of 1452

TM 5-4210-249-13&P-2
0165-7
DRAFT
0165
TFFT03913
NOTE
When removing cord reel, do not cut or disconnect any wires unless instructed to do so in
the procedure.
Step 12.
Unstow cord reel cord (WP 0037).
Cut black wire at cord reel junction box.
Ensure
jumperwire between black wire at circuit breaker 2 and ground is still installed.
Check
for continuity from black wire (going to circuit breaker 2), to a known good ground.
If there is no continuity, replace power cord from circuit breaker 2 to cord
reel junction box (WP 0361).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top