TM-5-4210-249-13-P-2

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 2 OF 4

  TM-5-4210-249-13-P-2 - Page 539 of 1452

TM 5-4210-249-13&P-2
0165-15
DRAFT
0165
TFFT4752
NOTE
When removing cord reel, do not cut or disconnect any wires unless instructed to do so in
this procedure.
Step 20.
Unstow cord reel cord (WP 0037).
Cut white wire at cord reel junction box.
Check for
continuity from white wire (going to circuit breaker box) at cord reel junction box, to a
known good ground.
If there is no continuity, replace power cord from circuit breaker box to cord
reel junction box (WP 0361).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top