Step 17.
Remove cover from cord reel drum (WP 0377).
Cut red wire at cord reel drum.
Install a
jumperwire between red wire at cord reel drum and a known good ground.
Check for
continuity from red wire at cord reel receptacle box to a known good ground.
a.
If continuity is present, repair cord reel (WP 0376).
b.
If there is no continuity, replace cord reel cable (WP 0377).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION