TM 5-4210-249-13&P-3
0318-1
DRAFT
0318
FIELD LEVEL MAINTENANCE
PUMP OPERATOR’S PANEL AIR FLOW RESTRICTOR INDICATOR REPLACEMENT
INITIAL SETUP:
REMOVAL
1.
Remove hose (1) from elbow (2).
NOTE
Note position of elbow prior to removal to ensure proper installation.
2.
Remove elbow (2) from fitting (3).
3.
Remove nut (4), washer (5), and fitting (3) from pump operator’s panel (6).
4.
Remove air flow restrictor indicator (7) from fitting (3).
END OF TASK
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00574
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Compound, Sealing, Pipe Thread
(WP 0625, Item 21)
References
WP 0615, Fig. 56
Equipment Conditions
Pump operator’s panel housing opened
(WP 0325)