TM-5-4210-249-13-P-3

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 3 OF 4

FEBRUARY 2009

  TM-5-4210-249-13-P-3 - Page 144 of 1488

TM 5-4210-249-13&P-3
0320-2
DRAFT
0320
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.
Remove eight locknuts (14), washers (15), screws (16), hinge (13), and plate (17) from pump operator’s panel
cover B (18).
Discard locknuts.
NOTE
Both rubber hold-downs are removed the same way.
5.
Remove locknut (19), washer (20), screw (21), and rubber hold-down (22) from pump operator’s panel
cover B (18).
Discard locknut.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6.
Remove four locknuts (23), washers (24), screws (25), and handle (26) from pump operator’s panel
cover B (18).
Discard locknuts.
7.
Remove two seals (27) from pump operator’s panel cover B (18).
8.
Remove three seals (28) from cover A (9).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away
from open fire and use in well-ventilated area.
If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
9.
Clean seal residue from two pump operator’s panel covers A (9) and B (18).
TFFT02024B
TFFT02024C
WARNING
ICON 30, 44, 27