TM 5-4210-249-13&P-3
0386-1
DRAFT
0386
FIELD LEVEL MAINTENANCE
DUAL GOVERNOR PRESSURE SWITCH REPLACEMENT
INITIAL SETUP:
REMOVAL
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Tag and mark connectors prior to removal to ensure proper installation.
1.
Disconnect dual governor pressure switch power supply connector (1) from pump operator’s panel wire
harness connector (2).
2.
Disconnect dual governor pressure switch connector (3) from main wire harness connector (4).
3.
Disconnect dual governor pressure switch connector (5) from pump operator’s panel wire harness
connector (6).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT04455
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Tags, Identification (WP 0625, Item 51)
Locknut (2)
References
WP 0615, Fig. 43
Equipment Conditions
Pump operator’s panel housing
opened (WP 0325)
Pump house panel S removed (WP 0540)