0388-3/(4 blank)
DRAFT
0388
2.
Install gear (12) on shaft (13) with set screw (11).
3.
Install preformed packing (10) and adapter (9) on electric motor (7) with four screws (8).
4.
Install electric motor (7) and preformed packing (6) on drive housing (3) with four screws (5).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Install electric motor and drive housing on valve as noted prior to removal.
5.
Install drive housing (3) on valve (4) with four screws (2).
6.
Connect connector (1).
END OF TASK
FOLLOW-ON MAINTENANCE
Close pump house panel A (WP 0539)
END OF TASK
END OF WORK PACKAGE