TM 5-4210-249-13&P-3
0388-1
DRAFT
0388
FIELD LEVEL MAINTENANCE
ELECTRONICALLY-OPERATED BALL VALVE ELECTRIC MOTOR AND DRIVE ASSEMBLY REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
•
Tag and mark wires prior to removal to ensure proper installation.
•
All nine electrically-operated ball valve electric motors and drive assemblies are replaced
the same way.
•
No. 1 discharge electrically-operated ball valve electric motor and drive assembly shown.
1.
Disconnect connector (1).
NOTE
•
Electric motor and drive assembly are replaced as an assembly.
•
Note position of electric motor and drive housing on valve prior to removal to ensure
proper installation.
2.
Remove four screws (2) and drive housing (3) from valve (4).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
TFFT00389
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Adhesive, Thread, Locking (WP 0625, Item 7)
Tags, Identification (WP 0625, Item 51)
Preformed Packing (1)
Preformed Packing (1)
References
WP 0615, Fig. 50
Equipment Conditions
Pump house panel A opened (WP 0539)