TM-5-4210-249-13-P-3

TACTICAL FIRE FIGHTING TRUCK (TFF) MODEL M1142

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL WITH REPAIR PARTS AND SPECIAL TOOLS LIST (INCLUDING DEPOT REPAIR PARTS AND SPECIAL TOOLS); PART 3 OF 4

FEBRUARY 2009

  TM-5-4210-249-13-P-3 - Page 713 of 1488

TM 5-4210-249-13&P-3
0453-1
DRAFT
0453
FIELD LEVEL MAINTENANCE
INLET, DISCHARGE, AND TANK FILL AND RE-CIRCULATING CONTROL VALVE WIRE HARNESS
REPLACEMENT
INITIAL SETUP:
NOTE
No. 1 and No. 2 driver side discharge, tank fill and re-circulating, and driver main inlet
valve power supplies are accessed by opening pump house panel A.
No. 3 and No. 4 passenger side discharge and driver side pre-connect B valve power
supplies are accessed by removing pump house panel G.
Driver side pre-connect A valve power supply is accessed by removing pump house I,
located on driver side by transmission.
Passenger side auxiliary inlet valve power supply is accessed by removing pump house
panel M or pump house access door located below pump house panel J. (Orientation of
valve may vary.)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0622, Item 27)
Materials/Parts
Ties, Cable, Plastic (WP 0625, Item 58)
References
WP 0615, Fig. 56
Equipment Conditions
Pump house panel A opened (for No. 1 and No. 2
driver side discharge, tank fill and
re-circulating, and driver main inlet valve
power supply wire harnesses (WP 0539)
Equipment Conditions (continued)
Pump house panel G removed (for No. 3 and
No. 4 passenger side discharge valve power
supply wire harnesses (WP 0540)
Pump house panel I removed (for driver side
pre-connect A valve power supply wire
harness) (WP 0540)
Close pump house access door (for passenger
side inlet valve power supply wire harness, if
opened) (WP 0539)
Remove pump house panel M (for passenger side
inlet valve power supply wire harness)
(WP 0540)
Pump operator’s panel housing
opened (WP 0325)


Back to Top