TM 5-5420-202-10
0049
4. Install end connector puller (Figure 2, Item 3) on end connector (Figure 2, Item 1).
5. Use 1-1/2 inch socket to tighten two puller screws (Figure 2, Item 2) until 1 inch of track link pins
(Figure 2, Item 4) is visible behind end connector (Figure 2, Item 1).
NOTE
It may be necessary to tap seated end connector (Figure 2, Item 1) with hammer to loosen.
6. Remove end connector (Figure 2, Item 1) from track link pins (Figure 2, Item 4).
Figure 2.
End Connector Removal.
0049-3
REMOVAL - CONTINUED