TM 5-5420-202-20-1
Item
No.
35
Preventive Maintenance Checks and Services for M60A1 AVLB Hull-
Continued
Interval
Semiannual
Location
Item to
Check/Service
Air Cleaners (Left
and Right Sides)
- Continued
Procedure
Open air cleaner door (page 7-97).
Check that door cam arms are not
bent, cracked, or missing.
Check that air cleaner door seal is
not hardened, damaged, missing, or
does not have indentations.
Check that screw holes are drilled
through and free of dirt or obstruc-
tions.
Check that sealing lip on housing is
not damaged. If housing sealing lip
is damaged, notify support mainte-
nance.
Remove filter.
Not Fully Mission
Capable if:
3-48