TM 5-5420-202-20-2
POWERPLANT TESTS (GROUND HOP) (Sheet 10 of 16)
Stall Test (Sheet 2 of 5)
8.
Check oil levels in engine and transmission (LO 5-5420-202-12). Make sure levels are
up to full range on level gages.
Take all necessary safety precautions to
eliminate possible injury to personnel or
damage to equipment. Stand clear of
transmission output flanges whenever the
engine is running.
Personnel must wear
hearing protection.
9.
Start and operate engine until normal operating temperatures are reached
(TM 5-5420-202-10).
NOTE
An indicator on the shaft and four dots
on the body transmission valve casting
indicate shift position.
10. Set transmission in high range by grasping shift lever and pull or push lever to set
indicator to high range.
Go on to Sheet 11
5-34