RELAY AND CIRCUIT BREAKER MOUNTING PANEL REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
1.
Replace mounting panel (A) in position on hull floor.
2.
Using socket, install four screws (B) and lockwashers (C) securing mounting panel (A)
to hull floor.
3.
Install fire extinguisher relay (10-142).
4.
Install fire extinguisher solenoid relay (10-159).
5.
Install air cleaner motor solenoid relay (10-164).
6.
Install fuel shutoff and personnel heater solenoid relays (10-166).
End of Task
10-168