TM 5-5420-202-20-3
FUEL SHUTOFF AND PERSONNEL HEATER CIRCUIT BREAKERS REPLACEMENT (Sheet 1 of 2)
TOOLS:
2 in. cross-tip screwdriver
SUPPLIES:
Lockwashers (2 required)
PRELIMINARY PROCEDURE:
Rmove access plate from floor at commander’s station
(page 17-9).
REMOVAL:
1.
Disconnect electrical leads (A) from circuit breaker (B).
2.
Using screwdriver, remove two
screws (C) and lockwashers (D)
securing circuit breaker (B)
to mounting plate (E).
3.
Remove circuit breaker (B) from mounting plate (E).
TA249106
10-165