5-11.
MAINTENANCE OF LEVEL ASSEMBLY (CONT).
CLEANING
Clean all parts per TM 9-254.
REPAIR
1 If bracket is broken, damaged, or missing, repair is by replacement of next higher assembly.
2 Repair Is by replacement of authorized parts as required.
Refer to appendix B.
REASSEMBLY
Never snap level vial covers on to level vials.
1
If two pins (1) were removed, drill and ream bracket (2) and drive in two pins (1).
Refer to TM 9-254.
2
Position two level vial covers (3) in bosses of bracket (2) and slide two level vials (4) in bracket (2) through level
vial covers (3).
3
Install two eccentrics (5), two eccentric rings (6), and two externally threaded rings (7).