TM 9-1240-400-34&P
5-12.
MAINTENANCE OF TELESCOPE MOUNT SUBASSEMBLY LOWER ASSEMBLY.
This task covers:
a.
Disassembly
c.
Repair
b.
Cleaning
d.
Reassembly
INITIAL SETUP:
Tools and Special Tools
Tool kit, electronic: system maintenance
(SC 5180-95-CL-B29)
Adjustable spanner wrench (8284045)
Materials/Parts
Aircraft grease (item 8, appx C)
Sealing compound (item 10, appx C)
Self-locking nut (8215831)
Solder (item 12, appx C)
Soldering flux (item 6, appx C)
References
TM 9-254
TM 9-2350-304-10
Equipment Conditions
5-13 M137 telescope mount use assembly
disassembled
General Safety Instructions
Use adhesives, cleaning solvents,
and
sealing compounds in well-ventilated
area away from open flame.
Adhesives,
cleaning
solvents,
and
sealing
compounds are harmful to skin and
clothing, can bum easily, and may give
off harmful vapor.
DISASSEMBLY
NOTE
M137 telescope mount upper assembly
housing shown removed for clarity.
1
Unsolder two electrical wires (1) and remove
from four electrical contacts (2).
2
Remove four electrical contacts (2) and four
bushing insulators (3) from housing (4).
5-28