TM 9-1240-400-34&P
8
Apply sealing compound (item 10, appx C) to
threads of plugs (13 and 14).
9
Install detent plunger (15) and plug (13).
10
Install V-bearing (16), spring (17), and plug (14) in
housing (5).
11
Apply sealing compound (item 10, appx C) to
external threads of four bushing insulators (18).
12
Install four bushing insulators (18) and four electrical
contacts (19) in housing (5).
13
Using solder (item 12, appx C) and soldering flux
(item 6, appx C), solder two wires (20) to four
electrical contacts (19).
Trim to fit.
14
Apply sealing compound (item 10, appx C) to wires
where they enter housing (5).
15
Use boresight target to correct backlash.
Refer to
TM 9-2350-304-10.
5-31