TM-9-1240-401-34-P

TELESCOPE MOUNT M146: M118A2 AND M118A3; TELESCOPE MOUNT M145: M145A1; PANORAMIC TELESCOPE: M117 AND M117A2; FIRE CONTROL QUADRANT: M15; PERISCOPE: M42

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

JULY 1993

  TM-9-1240-401-34-P - Page 53 of 590

TM 9-1240-401-34&P
b. Repair
1 Remove corrosion grease, and dirt from all parts.
Refer to TM 9-254 for cleaning instructions.
2 Visually inspect for missing or damaged parts.
3 Repair or replace parts in accordance with author-
ized parts listed in appendix D.
c.
Assemblv
I
1
2
3
4
5
6
7
8
9
10
11
12
13
Install three clamps (30) on cable (9).
Install wire (29) to connector shell (23); then install
lug terminal (28) on wire.
Slide bushing (22), flat washer (24), preformed
packing' (25), connector shell (23), lug terminal (28)
and wire (29) onto cable (9).
Install preformed packing (25) and flat washer (24)
on connector shell (23).
Install bushing (22) on connector shell
(23). Do not
tighten bushing.
Install two insulation sleevings (27) on leads of ca-
ble (9).
Install
new gasket (26).
Install electrical plug connector (21) on cable (9) by
soldering leads of cable using solder and flux.
Install new gasket (20) on electrical plug connector
(21).
Slide connector shell (23) along cable (9) toward
electrical plug connector (21 ).
Install connector shell (23) on electrical plug con-
nector (21).
Install preformed packing (19) and flat washer (18)
on electrical shell connector (8).
Install bushing (17) on electrical shell connector
(8). Do not tighten bushing.
2-19


Back to Top