TM-9-1240-401-34-P

TELESCOPE MOUNT M146: M118A2 AND M118A3; TELESCOPE MOUNT M145: M145A1; PANORAMIC TELESCOPE: M117 AND M117A2; FIRE CONTROL QUADRANT: M15; PERISCOPE: M42

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

JULY 1993

  TM-9-1240-401-34-P - Page 54 of 590

2-20
TM 9-1240-401-34&P
2-13. CABLE ASSEMBLY MAINTENANCE INSTRUCTIONS - continued
c. Assembly - continued
14
15
Install two insulation sleevings(16) on leads of ca-
ble (9).
Install two electrical contacts (15) on bushing insu-
lator (7); then install two lug terminals (11) on two
electrical contacts (15) by installing two nuts (14).
16 Install new gasket (1 3), angle bracket (1 O), and
new gasket (12) on bushing insulator (7).
17
18
19
20
Solder cable (9) leads on two lug terminals(11)
using solder and flux. Refer to wiring diagram and
check continuity of cable assembly.
Slide electrical shell connector
(8)
along cable to-
ward angle bracket (10) and secure with four new
Iockwashers
(6)
and four machine screws (5).
Install receptacle shell (4) and plate (3) on bushing
insulator (7) and secure with shoulder pin (2) and
machine screw (1).
Tighten bushings (17 and 22).


Back to Top