TM-9-2320-209-20-3-1

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; TROUBLESHOOTING; ORGANIZATIONAL LEVEL; VOLUME 3 OF 3; PART 1 OF 4

MAY 1981

  TM-9-2320-209-20-3-1 - Page 394 of 830

TM 9-2320-209-20-3-1
c.
Replacement.
1.
2.
WARNING
Dry cleaning solvent is flammable, Do not use near
an open flame. Keep a fire extinguisher nearby when
solvent is used. Use only in well-ventilated area.
Failure to do this will result in injury to personnel
and damage to equipment.
NOTE
Clean thermostat housing (1) using solvent. Make
sure surfaces that meet hoses or gaskets are smooth
and clean.
Put seal (2) into thermostat housing (1) so that lip of seal faces outward
toward thermostat (3).
Put thermostat (3) into thermostat housing (1) as shown.
GO TO FRAME 2
TA 08556 2
6-34