TM-9-2320-209-20-3-1

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; TROUBLESHOOTING; ORGANIZATIONAL LEVEL; VOLUME 3 OF 3; PART 1 OF 4

MAY 1981

  TM-9-2320-209-20-3-1 - Page 425 of 830

TM 9-2320-209-20-3-1
FRAME 12
1.
2.
3.
GO
Pull top of radiator (1) forward just enough to slip preformed hose (2) onto
radiator inlet fitting (3) .
Slip other end of preformed hose (2) on thermostat housing outlet fitting (4).
Put two clamps (5) on preformed hose (2) as shown. Do not tighten clamp
screws (6) at this time.
TO FRAME 13
6-65