TM-9-2320-209-20-3-1

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; TROUBLESHOOTING; ORGANIZATIONAL LEVEL; VOLUME 3 OF 3; PART 1 OF 4

MAY 1981

  TM-9-2320-209-20-3-1 - Page 422 of 830

TM 9-2320-209-20-3-1
1.
2.
3.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when
solvent is used. Use only in well-ventilated places.
Failure to do this may result in injury to personnel
and damage to equipment.
Using solvent , clean surfaces that mate hoses or gaskets so they are smooth
and clean.
Put seal (1) into thermostat housing (2) so that lip of seal faces outward
toward thermostat (3).
Put thermostat (3) into thermostat housing (2) as shown.
GO TO FRAME 10