TM-9-2320-209-34-2-2

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; MAINTENANCE; DIRECT SUPPORT AND GENERAL SUPPORT LEVEL; VOLUME 2 OF 2; PART 2 OF 3

MAY 1981

  TM-9-2320-209-34-2-2 - Page 269 of 899

TM 9-2320-209-34-2-2
1.
Fill tank (1) with test fluid ESR-34C.
2.
Close intake port gate valve (2) and discharge port gate valve (3).
3.
Turn on motor (4) and run at 540 RPM.
Check dry vacuum pressure.
4.
Send back pump (5) if dry vacuum pressure is lower than 10.5 in. Hg (5.15 psi).
Record dry vacuum pressure .
5.
Turn off motor (4).
GO TO FRAME 4