TM 9-2320-209-34-2-2
FRAME 6
1.
Put bypass valve (1), bypass valve spring (2) , and bypass valve spring
guide (3) in casing (4). Put new bypass valve cover gasket (5) and
bypass valve cover (6) in place.
2.
Screw in four lockwashers and screw (7).
3.
Put in bypass valve adjusting set screw (8) in cover.
NOTE
Do not put in bypass valve cap (9) and gasket (10)
until after test and adjustment para 17-26g.
GO TO FRAME 7
17-247